Gas Solutions Plus ← Team Dashboard
In the field

Quick reference

The numbers you look up on a driveway. Save this page to your home screen.

Print the field reference

Cathodic protection, the 15 install stages, clearances, buried-tank rules and what to do with another company’s tank — two pages, made to live in the truck.

Open the PDF Download

Cathodic protection — buried tanks

Passing reading−0.85 volts DC or more negative, against a copper/copper-sulfate half cell. −0.92 passes. −0.78 fails.
Typical rangeReadings run about −1.80 to 0.00. Anything between −1.80 and −0.85 is protected.
Test scheduleAt installation · again 12–18 months later · then at least every 36 months. Shorter if the AHJ says so.
If it failsRe-test first (wet the soil, check the cell, check contact) → look for a short to other buried metal → anodes → repair as soon as practical → retest and restart the schedule.
RecordsKeep at least the last two inspections on file.

Rough appliance demand

Nameplate always wins. These are for sizing conversations before you have one.

ApplianceTypical BTU/hr
Range / cooktop65,000
Tankless water heater150,000 – 199,000
Tank water heater (40 gal)40,000
Pool heater (400k)400,000
Standby generator (22–24 kW)250,000 – 300,000
Fire pit / bowl65,000 – 150,000
Linear fire feature90,000 – 200,000
Outdoor grill (built-in)60,000 – 90,000
Clothes dryer35,000
Fireplace insert40,000

Tank quick facts

TankUsable at 80%Usually suits
120 gal (420 lb)96 galOne or two appliances — cooking, dryer, tankless
250 gal200 galSmall whole-home, pool heater
500 gal400 galWhole home, generator, pool
1000 gal800 galLarge estate, commercial, multiple heavy loads

Tanks fill to 80%. A gauge percentage is a percentage of that usable volume — a 500 at 90% holds about 360 gallons.

On every visit

Pressure testRecord the test pressure and how long it held. “Held with no drop” is the only pass.
Leak checkEvery joint and fitting. Anything found gets repaired before you leave or written up as a return visit.
RegulatorRecord the reading in inches of water column. Vent clear and pointed down.
ClearancesCheck distances to doors, windows, ignition sources and equipment — and that nothing has grown or been built into the space.
PhotosTank, regulator, anything you found. They attach to the job for the office.

If a customer smells gas

Leave the area immediately and call 911. Don’t switch anything on or off on the way out. Once clear, call us. Never tell a customer to go back in and check something.

Forms and tools

My queue Service report Safety inspection Walkthrough Site visit Documents Customer file Planning tool